Special Features
1db passband: 2 to 4 ghz (channel 1), 12 to 18 ghz (channel 2); rejection: 20db at .5 to 1.5 ghz (channel 1), 20db at 5 to 18 ghz (channel 1), 20 db at .5 to 6 ghz (channel 2), 20db at 15 to 20ghz (channel 2), 30db at 2 to 12 ghz (opposite bands); insertion loss: 1db max
End Application
An/blq-10a (v) 1 fy04 mod w/entr/lpi
Part Name Assigned By Controlling Agency
Diplexer, rlc model dp-1184
Supplementary Features
Return loss: 10db max in passbands; variation in group delay: 3 ns max over any 400 mhz (passbands channel 1 and 2); connectors sma (female); approx size .6" x .6" x5.3" excluding connectors