Variable Attenuators - Page 62 of 104
2587 part numbers
150C0295
NSN 5985-01-192-7794
Cross Reference:
DA0295
-
printed circuit board application design
-
irregular body style
-
2.000 inches overall length
-
0.400 inches overall height
-
1.000 inches overall width
8495B-002
NSN 5985-01-195-7375
Cross Reference:
8495BOPT002, 91533279
-
transmission line application design
-
coaxial type body style
-
5.100 inches overall length
-
1.700 inches overall height
-
2.900 inches overall width
11437005
NSN 5985-01-195-9134
Cross Reference:
A-3520, AUM-15A/15603
-
transmission line application design
-
1.50 voltage standing wave ratio
-
2.0 watts average power rating
-
0.5 insertion loss at minimum attenuation in maximum decibels
-
+0.0/+20.0 overall attenuation range in decibels
77886-15
NSN 5985-01-196-5945
Cross Reference:
70-16224-01
-
audio application design
-
steel body material
-
cylindrical w/side terminals body style
-
1.969 inches overall length
-
2.031 inches overall width
292242P1
NSN 5985-01-196-9775
Cross Reference:
FS-761397-01
-
coaxial type body style
-
3.000 inches overall length
-
0.400 inches overall height
-
0.550 inches overall width
-
2 flange terminal type and quantity
238285-1
NSN 5985-01-199-0009
Cross Reference:
33300D-055, 33300DOPT055, 50P-087
-
transmission line application design
-
coaxial type body style
-
8.192 inches overall length
-
6.070 inches center to center distance between mounting facilities parallel to length
-
1.100 inches center to center distance between mounting facilities parallel to width
G1AA
NSN 5985-01-199-4627
Cross Reference:
7546076P0001, 7546076P1, WJ-G1AA
-
printed circuit board application design
-
-55.0/+71.0 degrees celsius operating tempurature range
-
amplifier converter, radar set end application
-
2.5 insertion loss at minimum attenuation in maximum decibels
-
+2.0/+8.0 overall attenuation range in decibels
ATN4002X
NSN 5985-01-199-5925
Cross Reference:
033028001
-
transmission line application design
-
+0.0/+8.0 overall attenuation range in decibels
-
9 pin terminal type and quantity
-
fa9964, preamplifier fsc application data
GA810DU1
NSN 5985-01-199-9100
Cross Reference:
PA-5010-5.0V-50MA
-
transmission line application design
-
irregular body style
-
3.781 inches overall length
-
2.594 inches center to center distance between mounting facilities parallel to length
-
0.437 inches center to center distance between mounting facilities parallel to width
6804-15K
NSN 5985-01-200-0855
Cross Reference:
7804-1662-1
-
transmission line application design
-
coaxial type body style
-
2.000 inches overall length
-
between 0.780 inches and 0.900 inches center to center distance between mounting facilities parallel to length
-
2.250 inches overall height
-
transmission line application design
-
irregular body style
-
between 2.940 inches and 3.060 inches overall width
-
1.50 voltage standing wave ratio
-
sma coaxial connector series designation
8494A
NSN 5985-01-203-9484
-
an/gss-3 (v) end application
-
7.000 inches overall length
-
1.000 inches overall height
-
4.000 inches overall width
-
vortac end application
-
2.000 inches overall length
-
between 0.730 inches and 1.060 inches overall height
-
1.750 inches overall width
-
an/alq-161 end application
-
2 connector, receptacle terminal type and quantity
-
transmission line application design
-
coaxial type body style
-
2.260 inches overall length
-
1.250 inches center to center distance between mounting facilities parallel to length
-
1.250 inches center to center distance between mounting facilities parallel to width
0N403389-1
NSN 5985-01-208-4237
Cross Reference:
0NTSEC/KOK-12, TSEC/KOK-12
-
audio application design
-
coaxial type body style
-
15.000 inches overall length
-
12.000 inches overall height
-
6.000 inches overall width
-
transmission line application design
-
coaxial type body style
-
2.500 inches overall length
-
0.500 inches overall height
-
1.250 inches overall width
10272609-2
NSN 5985-01-210-2633
Cross Reference:
STA-1100-00-002-05
-
transmission line application design
-
rectangular, terminals on one surface body style
-
2.400 inches overall length
-
between 1.557 inches and 1.567 inches center to center distance between mounting facilities parallel to length
-
1.100 inches overall height
FS-761397-01
NSN 5985-01-212-0630
Cross Reference:
292242P1, PX9
-
coaxial type body style
-
3.000 inches overall length
-
0.400 inches overall height
-
0.550 inches overall width
-
2 flange terminal type and quantity