Cross Sectional Shape
Internal, rectangular external, rectangular
End Application
Radar set an/aps-116
Tubing Wall Construction Style
Seamless single tubing segment
Flange Inside Width
1.003 inches first flange
Flange Inside Width
1.253 inches second flange
Flange Inside Height
0.503 inches first flange
Flange Inside Height
0.628 inches second flange
Flange Outside Width
1.610 inches and 1.640 inches first flange
Flange Outside Width
1.860 inches and 1.890 inches second flange
Flange Outside Height
1.610 inches and 1.640 inches first flange
Flange Outside Height
1.860 inches and 1.890 inches second flange
Flange Depth
0.423 inches and 0.453 inches first flange
Flange Depth
0.423 inches and 0.453 inches second flange
Flange Connecting Hole Diameter
0.169 inches all flanges all connection facilities
Voltage Standing Wave Ratio
1.08
Maximum Operating Pressure
26.4 pounds per square inch gage
Waveguide Outside Width
Between 0.996 inches and 1.004 inches
Waveguide Inside Width
Between 0.896 inches and 0.904 inches
Waveguide Inside Height
Between 0.396 inches and 0.404 inches
Waveguide Outside Height
Between 0.496 inches and 0.504 inches
Waveguide Longer Offset Distance
Between 4.350 inches and 4.410 inches
Flange Connecting Facility And Quantity
8 unthreaded hole all flanges all connection facilities
Flange Style
Cover type first flange
Flange Style
Cover type second flange
Waveguide Offset Distance
Between 1.530 inches and 1.600 inches
Flexibility
Rigid single tubing segment
Style Designator
Bend type
Fsc Application Data
Antennas, waveguides, and related equipment
Description
Waveguide Assembly