Cross Sectional Shape
Internal, rectangular external, rectangular
Tubing Wall Construction Style
Corrugated first tubing segment
Tubing Wall Construction Style
Seamless second tubing segment
Tubing Twist Type
Twistable first tubing segment
Tubing Twist Angle In Deg
90.0 first tubing segment
Flange Inside Width
1.250 inches all flanges and 1.256 inches all flanges
Flange Inside Height
0.617 inches all flanges and 0.623 inches all flanges
Flange Outside Width
1.860 inches all flanges and 1.890 inches all flanges
Flange Outside Height
1.860 inches all flanges and 1.890 inches all flanges
Flange Depth
0.415 inches all flanges and 0.445 inches all flanges
Flange Connecting Hole Diameter
0.164 inches all flanges all connection facilities and 0.174 inches all flanges all connection facilities
Voltage Standing Wave Ratio
1.12
Insertion Loss In Decibels
0.10
Maximum Operating Pressure
40.0 pounds per square inch gage
Waveguide Outside Width
Between 1.246 inches and 1.254 inches
Waveguide Inside Width
Between 1.118 inches and 1.126 inches
Waveguide Inside Height
Between 0.493 inches and 0.501 inches
Waveguide Outside Height
Between 0.621 inches and 0.629 inches
Flange Connecting Facility And Quantity
4 unthreaded hole all flanges all connection facilities
Waveguide First Leg Length
3.500 inches
Flange Style
Cover type all flanges
Waveguide Second Leg Length
2.690 inches
Waveguide Third Leg Length
8.125 inches
Waveguide Fourth Leg Length
2.500 inches
Flexibility
Flexible first tubing segment
Flexibility
Rigid second tubing segment
Style Designator
Three bend type
Supplementary Features
Frequency 8.49 to 9.61 ghz
Description
Waveguide Assembly