digital radio and multiplexer acquisition end application
-
digital radio and multiplexer acquisition end application
-
f-16 blk 40/60 cmn end application
-
2 flange quantity
-
17.120 inches waveguide length
-
15.950 inches waveguide center to center distance
-
rigid single tubing segment flexibility
TDR14798
NSN 5985-01-270-4685
Cross Reference:
16VE240-65
-
f-16c aircraft blk 40/60 cmn end application
-
2 flange quantity
-
1.25 voltage standing wave ratio
-
0.26 insertion loss in decibels
-
15.990 inches waveguide length
-
internal, rectangular external, rectangular cross sectional shape
-
seamless all tubing segment tubing wall construction style
-
2 flange quantity
-
0.900 inches waveguide outside width
-
0.400 inches waveguide outside height
-
internal, rectangular external, rectangular cross sectional shape
-
2 flange quantity
-
between 1.178 inches and 1.182 inches waveguide outside width
-
between 0.562 inches and 0.566 inches waveguide outside height
-
10.870 inches waveguide longer offset distance
-
internal, round external, round cross sectional shape
-
1 flange quantity
-
1.07 voltage standing wave ratio
-
49.590 inches waveguide length
-
offset bend type style designator
-
2 flange quantity
-
1.05 voltage standing wave ratio
-
11.440 inches waveguide longer offset distance
-
48.250 inches waveguide offset distance
-
bend type style designator
-
2 flange quantity
-
1.10 voltage standing wave ratio
125610
NSN 5985-01-270-7632
Cross Reference:
169510-001, AF-19-C-430-XXX
-
fairchild satopercntr end application
-
2 flange quantity
-
1.05 voltage standing wave ratio
-
5.0 pounds per square inch gage maximum operating pressure
-
2.000 inches waveguide center to center distance
483226-3
NSN 5985-01-271-1757
Cross Reference:
236073, TS68697-2
-
internal, rectangular external, rectangular cross sectional shape
-
corrugated single tubing segment tubing wall construction style
-
2 flange quantity
-
1.10 voltage standing wave ratio
-
25.0 pounds per square inch gage maximum operating pressure
R10-900
NSN 5985-01-271-5394
Cross Reference:
10134362
-
seamless all tubing segment tubing wall construction style
-
2 flange quantity
-
rigid all tubing segment flexibility
R10-901
NSN 5985-01-271-5395
Cross Reference:
10138372
-
seamless all tubing segment tubing wall construction style
-
2 flange quantity
-
rigid all tubing segment flexibility
R10-904
NSN 5985-01-271-5396
Cross Reference:
10134358, 84-10/21
-
seamless all tubing segment tubing wall construction style
-
2 flange quantity
-
9.810 inches waveguide length
-
9.690 inches waveguide center to center distance
-
rigid all tubing segment flexibility
-
internal, rectangular external, rectangular cross sectional shape
-
2b first flange single connection facility thread class
-
seamless single tubing segment tubing wall construction style
-
2 flange quantity
-
0.362 inches second flange flange inside width
-
internal, rectangular external, rectangular cross sectional shape
-
seamless single tubing segment tubing wall construction style
-
2 flange quantity
-
0.362 inches second flange flange inside width
-
0.222 inches first flange flange inside height