Waveguide Assemblies - Page 297 of 430

10727 part numbers
87CD0238-1 NSN 5985-01-306-2016
  • mc130h acft end application
  • 2 flange quantity
  • 1.33 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 56.320 inches waveguide length
87CD0239-1 NSN 5985-01-306-2017
  • mc130h acft end application
  • 2 flange quantity
  • 59.650 inches waveguide length
  • rigid single tubing segment flexibility
  • aluminum single tubing segment and flange material
86CD0396-1 NSN 5985-01-306-2018
  • mc130h acft end application
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 56.000 inches waveguide length
86CD0288-1 NSN 5985-01-306-2019
  • mc130h acft end application
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 31.900 inches waveguide length
86CD0395-1 NSN 5985-01-306-3903
  • mc130h acft end application
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 44.000 inches waveguide length
90CD0021-1 NSN 5985-01-306-3904 Cross Reference: 86CD0210-1
  • mc130h acft end application
  • 2 flange quantity
  • 1.18 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 9.300 inches waveguide length
90CD0023-1 NSN 5985-01-306-3905 Cross Reference: 86CD0211-1
  • mc130h acft end application
90CD0026-1 NSN 5985-01-306-3906 Cross Reference: 86CD0212-1
  • mc130h acft end application
  • 2 flange quantity
  • 1.12 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 15.450 inches waveguide longer offset distance
90CD0028-1 NSN 5985-01-306-3907 Cross Reference: 86CD0213-1
  • mc130h acft end application
  • 2 flange quantity
  • 1.16 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 17.750 inches waveguide length
86CD0265-1 NSN 5985-01-306-3908
  • mc130h acft end application
  • 2 flange quantity
  • 1.30 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 20.130 inches waveguide length
92CD0010-1 NSN 5985-01-306-3909
  • mc130h acft end application
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 14.250 inches waveguide longer offset distance
86CD0269-1 NSN 5985-01-306-3910
  • mc130h acft end application
  • 2 flange quantity
  • 1.21 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 24.430 inches waveguide length
86CD0270-1 NSN 5985-01-306-3911
  • mc130h acft end application
  • 2 flange quantity
  • 1.21 voltage standing wave ratio
  • 40.000 inches waveguide longer offset distance
  • 32.070 inches waveguide offset distance
86CD0279-1 NSN 5985-01-306-5382
  • mc130h acft end application
  • 2 flange quantity
  • 1.39 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 133.000 inches waveguide length
86CD0388-1 NSN 5985-01-306-5384
  • mc130h acft end application
  • 2 flange quantity
  • 1.20 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 58.120 inches waveguide length
86CD0389-1 NSN 5985-01-306-5385
  • mc130h acft end application
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 55.380 inches waveguide longer offset distance
86CD0390-1 NSN 5985-01-306-5386
  • mc130h acft end application
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 18.250 inches waveguide longer offset distance
86CD0391-1 NSN 5985-01-306-5387
  • mc130h acft end application
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 44.750 inches waveguide length
86CD0392-1 NSN 5985-01-306-5388
  • mc130h acft end application
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 57.060 inches waveguide length
86CD0393-1 NSN 5985-01-306-5389
  • mc130h acft end application
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • rigid single tubing segment flexibility
86CD0394-1 NSN 5985-01-306-5390
  • mc130h acft end application
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 18.330 inches waveguide longer offset distance
86CD0272-1 NSN 5985-01-306-5391
  • mc130h acft end application
  • 2 flange quantity
  • 1.43 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 16.500 inches waveguide longer offset distance
92CD0012-1 NSN 5985-01-306-5392
  • mc130h acft end application
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 19.250 inches waveguide longer offset distance
92CD0017-1 NSN 5985-01-306-5393
  • mc130h acft end application
  • 2 flange quantity
  • 1.30 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 15.250 inches waveguide longer offset distance
92CD0020-1 NSN 5985-01-306-5394
  • mc130h acft end application
  • 2 flange quantity
  • 1.21 voltage standing wave ratio
  • 25.0 pounds per square inch gage maximum operating pressure
  • 63.250 inches waveguide longer offset distance