Waveguide Assemblies - Page 308 of 430

10727 part numbers
122575-101 NSN 5985-01-328-6302
  • an/fsq-15 (v) end application
  • rigid all tubing segment flexibility
5611542 NSN 5985-01-329-7760 Cross Reference: 11KA-3-C-1-3, ST285-3.000, ST28S-3.000
  • internal, rectangular external, rectangular cross sectional shape
  • 2b all flanges all connection facilities thread class
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • cover type all flanges flange style
636-1 NSN 5985-01-329-7761 Cross Reference: AW2057, ES8132-07
  • internal, rectangular external, rectangular cross sectional shape
  • 2b all flanges all connection facilities thread class
  • 90.0 single bend h-plane bend angle in deg
  • seamless all tubing segment tubing wall construction style
  • 2 flange quantity
637-1 NSN 5985-01-329-7762 Cross Reference: AW2059, ES8132-09
  • internal, rectangular external, rectangular cross sectional shape
  • 2b all flanges all connection facilities thread class
  • 90.0 single bend h-plane bend angle in deg
  • seamless all tubing segment tubing wall construction style
  • 2 flange quantity
636 NSN 5985-01-329-8991 Cross Reference: AW2056, ES8132-06
  • internal, rectangular external, rectangular cross sectional shape
  • 90.0 all bends h-plane bend angle in deg
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • unable to decodeunable to decode unable to decode
635-1 NSN 5985-01-330-0242 Cross Reference: AW2055, ES8132-05
  • internal, rectangular external, rectangular cross sectional shape
  • 2b all flanges all connection facilities thread class
  • 90.0 single bend e-plane bend angle in deg
  • seamless all tubing segment tubing wall construction style
  • 2 flange quantity
G372371-50 NSN 5985-01-330-3321
  • internal, rectangular external, rectangular cross sectional shape
  • 90.0 single bend e-plane bend angle in deg
  • 2 flange quantity
  • 0.225 inches waveguide outside width
  • 0.113 inches waveguide outside height
587R392H01 NSN 5985-01-330-6790
768C NSN 5985-01-330-8638
90FP2109 NSN 5985-01-330-9257 Cross Reference: 3173028-100
  • internal, rectangular external, rectangular cross sectional shape
  • an/apq-180 radar set end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • between 0.996 inches and 1.004 inches waveguide outside width
4245416-004 NSN 5985-01-331-7012 Cross Reference: 125679-4, 475-112-4, TDR22320-2
  • 2b first flange all connection facilities thread class
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.20 voltage standing wave ratio
  • between 1.187 inches and 1.193 inches waveguide outside width
4245416-003 NSN 5985-01-331-7013 Cross Reference: 125679-3, 475-112-2, TDR22320-1
  • 2b first flange all connection facilities thread class
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.20 voltage standing wave ratio
  • between 1.187 inches and 1.193 inches waveguide outside width
4245416-007 NSN 5985-01-331-7014 Cross Reference: 125486-3, 750-112-2, TDR14785-1
  • 2b first flange second connection facility thread class
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.20 voltage standing wave ratio
  • between 1.187 inches and 1.193 inches waveguide outside width
5974738-3 NSN 5985-01-331-7792
  • seamless all tubing segment tubing wall construction style
  • 2 flange quantity
  • 5.0 pounds per square inch gage maximum operating pressure
  • rigid all tubing segment flexibility
  • bend type style designator
5974808-4 NSN 5985-01-331-7793
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 5.0 pounds per square inch gage maximum operating pressure
  • rigid single tubing segment flexibility
  • bend type style designator
5365919-12 NSN 5985-01-332-1126
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.05 voltage standing wave ratio
  • 5.0 pounds per square inch gage maximum operating pressure
  • 39.760 inches waveguide longer offset distance
5974755-3 NSN 5985-01-332-1127
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 5.0 pounds per square inch gage maximum operating pressure
  • 18.260 inches waveguide longer offset distance
  • 23.760 inches waveguide offset distance
5974756-3 NSN 5985-01-332-1128
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.05 voltage standing wave ratio
  • 7.140 inches waveguide longer offset distance
  • 24.280 inches waveguide offset distance
5974757-3 NSN 5985-01-332-1129
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 200.0 pounds per square inch gage maximum operating pressure
  • 12.050 inches waveguide longer offset distance
  • 32.040 inches waveguide offset distance
5974809-3 NSN 5985-01-332-1130
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 15.0 pounds per square inch gage maximum operating pressure
  • 14.050 inches waveguide longer offset distance
  • 14.320 inches waveguide offset distance
951431-56 NSN 5985-01-332-1131
  • internal, rectangular external, rectangular cross sectional shape
  • 2b all flanges all connection facilities thread class
  • radio terminal set an/trc-170 end application
  • seamless second tubing segment tubing wall construction style
  • 2 flange quantity
5365925-11 NSN 5985-01-332-2239
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 200.0 pounds per square inch gage maximum operating pressure
  • 9.540 inches waveguide longer offset distance
  • 12.460 inches waveguide offset distance
5365927-17 NSN 5985-01-332-2240
  • internal, rectangular external, rectangular cross sectional shape
  • 90.0 single bend h-plane bend angle in deg
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.08 voltage standing wave ratio
5365965-8 NSN 5985-01-332-2241
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.07 voltage standing wave ratio
  • 200.0 pounds per square inch gage maximum operating pressure
  • 50.390 inches waveguide length
5365972-18 NSN 5985-01-332-2242
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.08 voltage standing wave ratio
  • 5.0 pounds per square inch gage maximum operating pressure
  • 11.170 inches waveguide longer offset distance