270775-2 NSN 5985-01-407-7361
  • internal, rectangular external, rectangular cross sectional shape
  • 2b first flange all connection facilities thread class
  • seamless all tubing segment tubing wall construction style
  • 2 flange quantity
  • between 0.699 inches and 0.705 inches waveguide outside width
3594267-2 NSN 5985-01-407-8828
  • f15s ant test end application
  • adapter, mismatch, interlock assembly special features
106494-165 NSN 5985-01-407-8869 Cross Reference: 903005945-165
  • mc-130-e end application
  • seamless first tubing segment tubing wall construction style
  • 2 flange quantity
  • 2.00 voltage standing wave ratio
  • 0.31 insertion loss in decibels
106495-185 NSN 5985-01-407-8870 Cross Reference: 903005946-185
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.35 voltage standing wave ratio
  • 1.00 insertion loss in decibels
106494-137 NSN 5985-01-407-8871 Cross Reference: 903005945-137
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 0.50 insertion loss in decibels
106495-353 NSN 5985-01-407-8872 Cross Reference: 903005946-353
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • straight twist single tubing segment tubing twist type
  • 2 flange quantity
  • 1.39 voltage standing wave ratio
106495-371 NSN 5985-01-407-8873 Cross Reference: 903005946-371
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 0.62 insertion loss in decibels
106495-169 NSN 5985-01-407-8936 Cross Reference: 903005946-169
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.78 voltage standing wave ratio
  • 0.95 insertion loss in decibels
106495-193 NSN 5985-01-407-8937 Cross Reference: 903005946-193
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.24 voltage standing wave ratio
  • 0.38 insertion loss in decibels
106495-165 NSN 5985-01-407-8938 Cross Reference: 903005946-165
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.78 voltage standing wave ratio
  • 1.10 insertion loss in decibels
106495-211 NSN 5985-01-407-8940 Cross Reference: 903005946-211
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.21 voltage standing wave ratio
  • 0.22 insertion loss in decibels
106495-301 NSN 5985-01-407-8941 Cross Reference: 903005946-301
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.15 voltage standing wave ratio
  • 0.10 insertion loss in decibels
106495-325 NSN 5985-01-407-8943 Cross Reference: 903005946-325
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.33 voltage standing wave ratio
  • 0.48 insertion loss in decibels
106495-323 NSN 5985-01-407-8944 Cross Reference: 903005946-323
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 0.53 insertion loss in decibels
106495-317 NSN 5985-01-407-8945 Cross Reference: 903005946-317
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.34 voltage standing wave ratio
  • 0.28 insertion loss in decibels
106495-303 NSN 5985-01-407-8946 Cross Reference: 903005946-303
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.40 voltage standing wave ratio
  • 0.26 insertion loss in decibels
106495-331 NSN 5985-01-407-8951 Cross Reference: 903005946-331
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 0.71 insertion loss in decibels
106495-339 NSN 5985-01-407-8952 Cross Reference: 903005946-339
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.27 voltage standing wave ratio
  • 0.47 insertion loss in decibels
106495-351 NSN 5985-01-407-8953 Cross Reference: 903005946-351
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.30 voltage standing wave ratio
  • 0.68 insertion loss in decibels
233577-1 NSN 5985-01-408-0587
  • internal, rectangular external, rectangular cross sectional shape
  • 233500 end application
  • 1.630 inches waveguide length
  • straight type style designator
106495-157 NSN 5985-01-408-0779 Cross Reference: 903005946-157
  • mc-130-e end application
  • seamless single tubing segment tubing wall construction style
  • 2 flange quantity
  • 1.78 voltage standing wave ratio
  • 0.95 insertion loss in decibels
126196 NSN 5985-01-408-1856 Cross Reference: 17B4U5029
  • internal, rectangular external, rectangular cross sectional shape
  • between 3.620 inches and 3.680 inches waveguide length
  • straight type style designator
126197 NSN 5985-01-408-2888 Cross Reference: 17B4U5034-1
  • 2.530 inches waveguide longer offset distance
  • 1.800 inches waveguide offset distance
  • bend type style designator
724524-1 NSN 5985-01-408-3241
  • mc-130-e end application
736189-2 NSN 5985-01-408-3264
  • mc-130-e end application
  • ka band; combat talon special features