Description
2b single flange second connection facility thread class, aluminum alloy 6061 single tubing segment and flange material, chromate single tubing segment and flange all surfaces surface treatment, unc single flange second connection facility thread series designator.
Unable To Decode
Internal, rectangular double ridged external, rectangular double indented
Thread Direction
Right-hand single flange second connection facility
Unable To Decode
Seamless single tubing segment
Flange Inside Width
0.691 inches single flange
Flange Inside Height
0.321 inches single flange
Flange Outside Width
1.968 inches single flange
Flange Outside Height
1.390 inches single flange
Flange Depth
0.595 inches single flange
Flange Connecting Hole Diameter
0.156 inches single flange first connection facility
Voltage Standing Wave Ratio
1.25
Insertion Loss In Decibels
0.20
Coaxial Connector Series Designation
Sma
Connector End Design
Female
Adapter Length
Between 1.680 inches and 1.750 inches
Adapter Height
1.390 inches
Thready Qty Per Inch (tpi)
32 single flange second connection facility
Maximum Operating Pressure
30.0 pounds per square inch gage
Waveguide Outside Width
Between 1.187 inches and 1.193 inches
Thread Size
0.138 inches single flange second connection facility
Waveguide Inside Width
Between 1.087 inches and 1.093 inches
Waveguide Inside Height
Between 0.503 inches and 0.509 inches
Waveguide Outside Height
Between 0.603 inches and 0.609 inches
Flange Connecting Facility And Quantity
4 threaded hole single flange second connection facility
Flange Connecting Facility And Quantity
8 unthreaded hole single flange first connection facility
Flange Style
Contact, double ridge type single flange
Adapterheight
1.495 inches
Adapterwidth
1.968 inches
Style Designator
Waveguide to coaxial
Fsc Application Data
Antennas, waveguides, and related equipment
Description
Adapter,waveguide