Motor Starters - Page 33 of 185

4618 part numbers
2510-MB02 NSN 6110-01-135-5361 Cross Reference: 2510B0-2
  • used on aircraft carrier; cvn, nimitz class end application
186397 NSN 6110-01-136-1106
24055 NSN 6110-01-137-1923
  • 0 to full speed speed adjustments
  • 440.0 volts ac voltage rating
  • 60.0 hertz frequency rating
  • magnetic actuation method
  • automatic performance type
188B3060G1S2 NSN 6110-01-137-4718
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • not designed per nema std national electrical manufacturers association standards design
  • local control type
188B3059G1S2 NSN 6110-01-137-4719
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • local control type
MIL-C-2212 NSN 6110-01-137-4720 Cross Reference: 188B3074G1S2
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • not designed per nema std national electrical manufacturers association standards design
  • local control type
509-DOD NSN 6110-01-137-4721 Cross Reference: 709-DOD103
  • 0 to full speed speed adjustments
  • 6.594 inches overall length
  • 12.875 inches overall height
  • 6.172 inches overall width
  • 600.0 volts ac voltage rating
A90028-01 NSN 6110-01-138-3114
  • 60.0 hertz frequency rating
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • 30.0 amp size rating
6962ED1768A2 NSN 6110-01-138-5076
  • 0 to full speed speed adjustments
  • shock proof hazardous locations/environmental protection
  • 13.000 inches overall height
  • 440.0 volts ac voltage rating
  • 60.0 hertz frequency rating
MIL-C-2212 NSN 6110-01-138-5077 Cross Reference: 6967ED351A2
  • 0 to full speed speed adjustments
  • shock proof hazardous locations/environmental protection
  • 10.380 inches overall length
  • 18.120 inches overall height
  • 14.100 inches overall width
MIL-C-2212 NSN 6110-01-138-5078 Cross Reference: 6962ED2508A2
  • 0 to full speed speed adjustments
  • shock proof hazardous locations/environmental protection
  • 10.380 inches overall length
  • 20.120 inches overall height
  • 16.100 inches overall width
692ED1338A2 NSN 6110-01-138-7447
  • 0 to full speed speed adjustments
  • shock proof hazardous locations/environmental protection
  • 6.500 inches overall length
  • 13.000 inches overall height
  • 7.740 inches overall width
188B3010G1S2 NSN 6110-01-139-4123
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • local control type
22CP32BA NSN 6110-01-139-4124 Cross Reference: 22CF32BA
  • 0 to full speed speed adjustments
  • general purpose-nema type 1 hazardous locations/environmental protection
  • 3.625 inches overall length
  • 7.688 inches overall height
  • 8.750 inches overall width
MIL-C-2212 NSN 6110-01-139-6243 Cross Reference: 6967ED350A2
  • two speed speed adjustments
  • 7.000 inches overall length
  • 15.625 inches overall height
  • 11.750 inches overall width
  • 440.0 volts ac voltage rating
59453013400 NSN 6110-01-140-2212 Cross Reference: 1243
  • 440.0 volts ac voltage rating
  • 60.0 hertz frequency rating
  • magnetic actuation method
  • automatic performance type
  • continuous duty cycle
24157 NSN 6110-01-140-2213
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • local control type
202B5039G1S2 NSN 6110-01-140-2214
  • magnetic actuation method
  • continuous duty cycle
  • full operating voltage characteristic
  • local or remote control type
  • wired per suffix g1s2 special features
MIL-C-2212 NSN 6110-01-140-2216 Cross Reference: 6962ED2308A4, 6962ED2308A5
  • 0 to full speed speed adjustments
  • 440.0 volts ac voltage rating
  • 60.0 hertz frequency rating
  • magnetic actuation method
  • manual performance type
MIL-DTL-2212 NSN 6110-01-140-3009 Cross Reference: 6962H160A2
  • 0 to full speed speed adjustments
  • 9.500 inches overall length
  • 18.000 inches overall height
  • 12.000 inches overall width
  • 440.0 volts ac voltage rating
6962ED2430A2 NSN 6110-01-141-0624
  • 440.0 volts ac voltage rating
  • 60.0 hertz frequency rating
  • magnetic actuation method
  • automatic and manual performance type
  • 1 fuse accommodation quantity
6967ED186B2 NSN 6110-01-141-2400
  • two speed speed adjustments
  • 440.0 volts ac voltage rating
  • 60.0 hertz frequency rating
  • magnetic actuation method
  • automatic and manual performance type
14IP32AC NSN 6110-01-141-2401 Cross Reference: 14IF32AC
  • 0 to full speed speed adjustments
  • 5.062 inches overall length
  • 9.906 inches overall height
  • 4.500 inches overall width
  • between 460.0 volts and 575.0 volts ac voltage rating
14RF33BC NSN 6110-01-141-3230
  • 0 to full speed speed adjustments
  • general purpose-nema type 1 hazardous locations/environmental protection
  • 10.562 inches overall length
  • 37.812 inches overall height
  • 17.562 inches overall width
24102 NSN 6110-01-141-4494
  • dripproof hazardous locations/environmental protection
  • magnetic actuation method
  • automatic performance type
  • 3 size designator
  • continuous duty cycle