Power Switchboards - Page 14 of 20

497 part numbers
207272 NSN 6110-01-297-6680
DA8602102D001 NSN 6110-01-300-4423
  • power distribution end application
699-3001 NSN 6110-01-307-8899 Cross Reference: D-20303-11
  • zzzy criticality code justification
379.MSB.100 NSN 6110-01-308-6895
  • electrical control equipment end application
  • partially enclosed inclosure feature
  • 1 panel quantity
703453-102 NSN 6110-01-309-7620
2797D010-CG52 NSN 6110-01-312-4404
  • switchboard mn distrn 25 end application
M-2180-1 NSN 6110-01-313-2714
  • electrical control equipment end application
  • volts 120/450, frequency 60 hz, phase 1/3 special features
6976ED112-SSN759 NSN 6110-01-313-7038
  • three input phase
  • spray proof inclosure feature
  • 440.0 ac pounds per hour wet input voltage rating
  • 60.0 input frequency in hertz
6976ED130-SSN764 NSN 6110-01-313-7039
  • 82.000 inches overall height
  • 42.500 inches overall width
  • 15.000 inches overall thickness
  • steel panel material
  • three input phase
DA83-09-131-001 NSN 6110-01-314-0194
  • 412.000 inches overall length
  • 140.000 inches overall width
  • any acceptable inclosure feature
  • 23 panel quantity
6976ED112-SSN764 NSN 6110-01-314-7137
  • 42.500 inches overall width
  • electrical control equipment end application
  • three input phase
  • 1 panel quantity
  • 440.0 ac pounds per hour wet input voltage rating
6976ED130-SSN759 NSN 6110-01-314-7537
  • 82.000 inches overall height
  • 42.500 inches overall width
  • 15.000 inches overall thickness
  • steel panel material
  • three input phase
807869-2B NSN 6110-01-316-0724
  • 48.000 inches overall length
  • 82.000 inches overall height
  • electrical control equipment end application
  • 4 panel quantity
807831-5S NSN 6110-01-316-2131
  • 131.000 inches overall length
  • 81.000 inches overall height
  • 53.500 inches overall width
  • floor mounting method
  • electrical control equipment end application
807832-6S NSN 6110-01-316-2132
  • three input phase
  • 1 panel quantity
  • 440.0 ac pounds per hour wet input voltage rating
  • 60.0 input frequency in hertz
517-6558962 ITEM 1 NSN 6110-01-316-6959 Cross Reference: 87655-4631 ITEM 1
  • switchboard mounting method
  • any acceptable inclosure feature
  • 2 panel quantity
  • 2 electrical output quantity
CS-100-1965 NSN 6110-01-317-0947
  • 1 panel quantity
  • 2 electrical input quantity
706380-101 NSN 6110-01-319-2654 Cross Reference: 7614-947302 REV LF
  • 48.000 inches overall length
  • 29.000 inches overall height
  • any acceptable inclosure feature
  • 3 panel quantity
CS-050-1966 NSN 6110-01-319-3586
  • any acceptable mounting method
  • any acceptable panel material
  • any acceptable inclosure feature
  • 600 kw ac, 450 volts, 3 phase, 3 watt, 60 hz special features
  • any acceptable surface treatment
SP000282-020000 NSN 6110-01-320-2274
  • 31.750 inches overall length
  • 10.000 inches overall height
  • 26.375 inches overall width
  • any acceptable mounting method
  • steering control end application
706244-101 NSN 6110-01-320-3308
  • 47.875 inches overall length
  • 27.000 inches overall width
  • any acceptable mounting method
  • electrical control equipment end application
  • any acceptable inclosure feature
58027-D1004 NSN 6110-01-320-3309
  • 138.000 inches overall length
  • 87.080 inches overall height
58027-D0004 NSN 6110-01-320-3310
  • 171.000 inches overall length
  • 82.000 inches overall height
  • 48.000 inches overall width
  • panel mounting method
  • electrical control equipment end application
177B5441G1 NSN 6110-01-321-2697 Cross Reference: 177B5441G01
  • any acceptable mounting method
  • electrical control equipment end application
  • any acceptable panel material
  • dripproof inclosure feature
  • 4 sections, 440 vac, 60 hz, 3 phase special features
177B5445G1 NSN 6110-01-322-1314
  • any acceptable mounting method
  • electrical control equipment end application
  • steel panel material
  • dripproof inclosure feature
  • 440 vac, 60 hz, 3 phase, 2 sections special features