Flow rate indicating me test set (NSN 6680-01-380-6577)
Special Features
length of unit less drawbar 105.500 inches; length of unit with drawbar 154.500 inches
Width
69.000 inches
Length
105.500 inches
Major Components
Nozzle, hose reel, meter assembly, single point hose assembly, swivel joint, fuel pressure servicing adapter, pressure gage, temperature gage, static ground reel, chassis and running gear
Inclosure Feature
Multiple item w/housing
Test Type For Which Designed
Fuel delivery systems
Operating Test Capability
30 to 600 gallons per minute at 150 psig
Functional Description
Tester used to prove and calibrate permenantly installed displacement meters or meters mounted on hydrant refueling equipment; tester is designed for calibration of meters within operational flow range of 30 gpm to 600 gpm at operating pressures not exceeding 150 psi