Electric equipment rack instl no. 4b10006-101a, c5a acft
Functional Description
Component of the liquid level sensing system used with the fuel quantity gage; operates a self contained relay in response to a changing resistive input furnished by the liquid level sensor; operation causes a remote warning light to come on indicating that a low fuel level exists in the aircraft fuel tank
Reference Data And Literature
T.O. 5l16-8-3
General Description
Input voltage 115 vac, 400 hz; power consumption 4.5 watts; relay contact rating 1 ampere at 28 vdc; system response time-air to fuel 3 seconds and fuel to air 24 seconds