Special Features
Nitrogen-filled sealed metal case with gas-tight zero adjuster; immersion tested to one meter; -40 to 70 degrees celsius operating temperature range; -55 to 85 degrees celsius storing temperature range; 50-0-50 millivolt rating; thermister circuit ambient temperature compensated; external separate shunt (not included) required for operation
Description
2.845 inches nominal overall length.
Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
2600.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.380 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.380 inches
Overall Height
4.300 inches
Overall Width
4.300 inches
Scale Division Quantity
4 single indicator single range
Mounting Stud Length
0.656 inches
End Application
984 propulsion system
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.0/+1.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
2.220 inches
Meter Body Diameter Behind Mounting Flange
3.970 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
Linear single indicator single range
Measurement Range
-2000.0/+2000.0 amperes, dc single indicator single range