Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
2600.0
Center To Center Distance Between Mounting Facilities Parallel To Length
Between 2.730 inches and 2.750 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
Between 2.363 inches and 2.383 inches
Overall Height
3.500 inches
Overall Width
3.500 inches
Mounting Stud Length
0.500 inches
Environmental Protection
Dustproof
Shortest Horizontal Distance Between Mounting Centers
Between 1.360 inches and 1.380 inches
Furnished Items And Quantity
Nut 3
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud triangular
Frequency Response Range
+25.000/+400.000 hertz
Sensitivity Rating
5.0 amperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.210 inches
Meter Body Diameter Behind Mounting Flange
2.700 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 threaded stud
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
+0.0/+600.0 amperes, ac single indicator single range
Circuit Construction Type
Nonelectronic
Mounting Stud Diameter
0.112 inches
Scale Selection Method
Terminal
Features Provided
Transformer and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Meets ansi c-39.0 spec
Style Designator
Rectangular flush mtg
Fsc Application Data
Test sets, electronic systems, except specially designed