Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
2000.0
Mounting Hole Diameter
0.150 inches
Scale Division Quantity
30 single indicator 2nd range
Scale Division Quantity
80 single indicator 1st range
Frequency Rating
60.0 hertz
Overall Diameter
3.500 inches
Environmental Protection
Dust resistant
Mounting Bolt Circle Diameter
3.160 inches
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
50.0 millivolts
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
1.312 inches
Meter Body Diameter Behind Mounting Flange
2.750 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
3 unthreaded hole
Scale Graduation Type
Linear single indicator all ranges
Measurement Range
+0.0/+30.0 amperes, ac single indicator 2nd range
Measurement Range
+0.0/+80.0 amperes, ac single indicator 1st range
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
Single phase, red line at 52 amp, red line at 15 amp
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Fsc Application Data
Test set, electronic equipment