Circuit Current For Which Designed
Ac
Center To Center Distance Between Mounting Facilities Parallel To Length
Between 3.346 inches and 3.406 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
Between 3.346 inches and 3.406 inches
Overall Height
Between 4.250 inches and 4.750 inches
Overall Width
Between 4.250 inches and 4.750 inches
Mounting Stud Length
Between 0.500 inches and 0.750 inches
Environmental Protection
Dust resistant and shock resistant and vibration resistant
Furnished Items And Quantity
Nut 12; washer 4
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
5.0 amperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.0/+1.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
9.000 inches
Meter Body Diameter Behind Mounting Flange
3.980 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
+0.0/+6000.0 amperes, ac single indicator single range
Mounting Stud Diameter
0.250 inches
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
Red wedge at 4000 ampmark
Special Test Features
Conforms to mil-l-16034/4a, mr49w006ackah
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.