Special Features
Frequency response 9 khz to 110 mhz porm 2.0 db; autorange plus five ranges varying between 1.0 milliampre to 1.0 ampre ; rechargeable nickel-cadmium battery
Circuit Current For Which Designed
Dc
Furnished Items And Quantity
Model hi-3702 clamp-on current sensor with cushioned case 1; standard fast charger (115/230v) 1; user's manual 1; fitted carrying case 1; hi-4416 digital readout/control unit with fiber optic cable 1
Indicator Type
Digital display
Operating Voltage Rating In Volts
3.6 dc
Functional Description
Measures the induced body current of individuals working in environments where radio frequency electromagnetic fields are present such as induction heating facilities, industrial welding applications, broadcast transmitting and antenna locations