5087 part numbers
293B099A11 NSN 6625-00-943-3714 Cross Reference: 495-013, HR65099N3-3, S293B099A11
  • dc circuit current for which designed
  • 2000.0 dielectric withstanding voltage in volts
  • 3.500 inches overall length
  • 3.375 inches center to center distance between mounting facilities parallel to length
  • 3.375 inches center to center distance between mounting facilities parallel to width
EDN30-009 NSN 6625-00-943-4926
  • dc circuit current for which designed
  • 1.860 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 3.130 inches overall height
370-0046 NSN 6625-00-943-4949
  • dc circuit current for which designed
  • 2.595 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 3.000 inches overall height
370-09738 NSN 6625-00-943-9541
  • ac circuit current for which designed
  • 0.156 inches mounting hole diameter
  • 400.0 hertz frequency rating
  • 3.500 inches overall diameter
  • 3.156 inches mounting bolt circle diameter
MM2 NSN 6625-00-944-7270 Cross Reference: 22950-4
  • dc circuit current for which designed
  • 2.719 inches overall height
  • 2.719 inches overall width
  • 2.440 inches mounting bolt circle diameter
  • panel installation design
AEDSM30807 NSN 6625-00-944-8907 Cross Reference: AEDSN30807, B63A0006-1
  • dc circuit current for which designed
  • 500.0 dielectric withstanding voltage in volts
  • 2.260 inches overall length
  • 3.510 inches overall diameter
  • 3.160 inches mounting bolt circle diameter
8938118-22 NSN 6625-00-944-8908
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 3.790 inches overall length
  • 0.750 inches center to center distance between mounting facilities parallel to length
  • 3.805 inches center to center distance between mounting facilities parallel to width
944772-305 NSN 6625-00-944-9574
  • dc circuit current for which designed
  • 0.156 inches mounting hole diameter
  • 11 single indicator single range scale division quantity
  • 3.500 inches overall diameter
  • 3.156 inches mounting bolt circle diameter
KA241-291B461A23 NSN 6625-00-944-9648
  • ac circuit current for which designed
  • 3.375 inches center to center distance between mounting facilities parallel to length
  • 3.375 inches center to center distance between mounting facilities parallel to width
  • 4.421 inches overall height
  • 4.421 inches overall width
30003-401D80-1 NSN 6625-00-945-0176
  • project code 931 end application
  • agav criticality code justification
1964796 NSN 6625-00-945-0302 Cross Reference: KX241-160-0-160 X 1964796
  • dc circuit current for which designed
  • 3.500 inches overall length
  • between 3.361 inches and 3.391 inches center to center distance between mounting facilities parallel to length
  • between 3.361 inches and 3.391 inches center to center distance between mounting facilities parallel to width
  • between 4.250 inches and 4.750 inches overall height
CV433-4903003 NSN 6625-00-945-2747
CV931-4904003 NSN 6625-00-945-2759
DW90 NSN 6625-00-945-4020 Cross Reference: 188111LJLJ, 50-188111LJLJ, EDN30-019, EDN30-019REVB
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 1.605 inches overall length
  • 1.750 inches overall height
  • 1.750 inches overall width
2021 NSN 6625-00-945-4945 Cross Reference: 1921, 260629
  • dc circuit current for which designed
  • 2.450 inches overall length
  • 1.880 inches center to center distance between mounting facilities parallel to length
  • 1.880 inches center to center distance between mounting facilities parallel to width
  • 2.390 inches overall height
Q2649 NSN 6625-00-945-7389
  • dc circuit current for which designed
  • 0.156 inches mounting hole diameter
  • 3.500 inches overall diameter
  • 3.156 inches mounting bolt circle diameter
  • panel installation design
6473345 NSN 6625-00-945-9371 Cross Reference: 11943A, 1315944, 1501436, 1502195, 1502482, 1503311, 171328, 32372, 8002865, AP6579
  • dc circuit current for which designed
  • 2.030 inches overall length
  • 4 single indicator single range scale division quantity
  • 0.562 inches mounting stud length
  • 2.280 inches overall diameter
612X50 NSN 6625-00-946-0234 Cross Reference: 50-162141LSRL, 50-162141LSRL2LFF, 551-11701-21, 7901683-10, A3630, MEL90584-1
  • ac circuit current for which designed
  • 2600.0 dielectric withstanding voltage in volts
  • 2.480 inches overall length
  • 3.512 inches overall height
  • 3.512 inches overall width
E136-42-329PT10 NSN 6625-00-946-3227 Cross Reference: 29
  • dc circuit current for which designed
  • 1.600 inches overall length
  • 4.000 inches center to center distance between mounting facilities parallel to length
  • 3.500 inches center to center distance between mounting facilities parallel to width
  • 4.700 inches overall height
2480 NSN 6625-00-946-6036 Cross Reference: 625-104
04410 NSN 6625-00-946-6056 Cross Reference: 1327-4410, 4410
  • dc circuit current for which designed
  • 2.400 inches overall length
  • 2.240 inches center to center distance between mounting facilities parallel to length
  • 2.240 inches center to center distance between mounting facilities parallel to width
  • 3.250 inches overall height
B8119 NSN 6625-00-947-2998 Cross Reference: 1503430, AM1503430
  • dc circuit current for which designed
  • 2.000 inches overall diameter
  • white single indicator single range dial scale marking color
  • 1.820 inches meter depth behind mounting flange
  • black single indicator single range background color
DW91 NSN 6625-00-947-3677 Cross Reference: 118A, 803X41
DW91 NSN 6625-00-947-3678 Cross Reference: 116A, 818X44
DW91 NSN 6625-00-947-3679 Cross Reference: 115A, 818X99