5087 part numbers
857-504-AM NSN 6625-01-122-4941 Cross Reference: MM7702-5
  • ac circuit current for which designed
  • 2.210 inches overall length
  • 2.730 inches overall height
  • 3.150 inches overall width
  • 0.450 inches mounting stud length
SM-A-937253 NSN 6625-01-122-7294 Cross Reference: 1511-2901005, 2511
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 1.550 inches overall length
  • 1.312 inches center to center distance between mounting facilities parallel to length
  • 1.312 inches center to center distance between mounting facilities parallel to width
M10485-5 NSN 6625-01-122-7337
23-2013 NSN 6625-01-122-8286
  • dc circuit current for which designed
  • 1.830 inches overall length
  • 1.970 inches overall height
  • 3.540 inches overall width
  • 2.360 inches barrel width
17503 NSN 6625-01-123-1671 Cross Reference: 2123-17503
  • dc circuit current for which designed
  • 1.840 inches overall length
  • 2.240 inches center to center distance between mounting facilities parallel to length
  • 2.240 inches center to center distance between mounting facilities parallel to width
  • 3.000 inches overall height
641-114 NSN 6625-01-123-2099
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.050 inches overall length
  • between 0.143 inches and 0.157 inches mounting hole diameter
  • 50 single indicator single range scale division quantity
1227-2480 NSN 6625-01-123-5426 Cross Reference: 02480, 1227-02480
  • dc circuit current for which designed
  • not established reliability indicator
  • 2.240 inches overall length
  • 1.880 inches center to center distance between mounting facilities parallel to length
  • 1.880 inches center to center distance between mounting facilities parallel to width
1257 NSN 6625-01-123-5427 Cross Reference: 02599, 1257-02599, 1257-2599
  • ac circuit current for which designed
  • not established reliability indicator
  • 2.240 inches overall length
  • 1.880 inches center to center distance between mounting facilities parallel to length
  • 1.880 inches center to center distance between mounting facilities parallel to width
A4A.112 NSN 6625-01-123-5428
  • ac circuit current for which designed
  • 4.500 inches overall length
  • 3.374 inches center to center distance between mounting facilities parallel to length
  • 3.374 inches center to center distance between mounting facilities parallel to width
  • 4.375 inches overall height
MS1T NSN 6625-01-123-7976 Cross Reference: 118002-101
  • dc circuit current for which designed
  • 1.630 inches overall length
  • 1.750 inches overall height
  • 1.750 inches overall width
  • 20 single indicator single range scale division quantity
36-3342-0050 NSN 6625-01-123-8248
  • dc circuit current for which designed
  • 2.140 inches overall length
  • 2.005 inches overall height
  • 3.520 inches overall width
  • 35 single indicator single range scale division quantity
D5-15-8229 NSN 6625-01-124-0334 Cross Reference: 36.1865
  • dc circuit current for which designed
  • 1.790 inches overall length
  • 3.500 inches overall diameter
  • panel installation design
  • 40.0 amperes sensitivity rating
C11024-1 NSN 6625-01-124-2596 Cross Reference: Y5-0809-0000
  • ac circuit current for which designed
  • 3.800 inches overall length
  • 0.650 inches overall height
  • 3.650 inches overall width
  • 30 single indicator single range scale division quantity
39-0163-101 NSN 6625-01-124-2597 Cross Reference: 267, 624, 624-109
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.630 inches overall length
  • 0.125 inches mounting hole diameter
  • 40 single indicator single range scale division quantity
1088418G35 NSN 6625-01-124-3314 Cross Reference: 365-377, 908-255
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.850 inches overall length
  • 0.150 inches mounting hole diameter
  • 50 single indicator single range scale division quantity
806972-1 NSN 6625-01-124-9713 Cross Reference: QDA-9953
  • dc circuit current for which designed
  • 7.500 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 3.130 inches overall height
365-534 NSN 6625-01-125-1139 Cross Reference: 31A03-0034
  • dc circuit current for which designed
  • 2.312 inches overall length
  • 100 single indicator single range scale division quantity
  • 3.500 inches overall diameter
  • 3.125 inches mounting bolt circle diameter
MC06727 NSN 6625-01-125-5956 Cross Reference: 100166
  • dc circuit current for which designed
  • 1.750 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 2.875 inches overall height
350W NSN 6625-01-127-0668 Cross Reference: 23W, 321LH, W-8061A-13
W-8095A-9 NSN 6625-01-127-0669
  • panel installation design
  • round flush mtg style designator
400R-150A NSN 6625-01-127-2141
  • dc circuit current for which designed
  • 2.500 inches overall length
  • 0.475 inches mounting stud length
  • 4.560 inches overall diameter
  • 4.124 inches mounting bolt circle diameter
250201JRJR NSN 6625-01-128-6890 Cross Reference: 50-250-201JRJR
  • dc circuit current for which designed
  • 3.020 inches overall length
  • 2.112 inches center to center distance between mounting facilities parallel to length
  • 1.829 inches center to center distance between mounting facilities parallel to width
  • 2.690 inches overall height
16883 NSN 6625-01-128-7575 Cross Reference: 3323XA, 77C10888-1
  • dc circuit current for which designed
  • 4.980 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 0.150 inches mounting hole diameter
16883 NSN 6625-01-128-7576 Cross Reference: 3323XA, 77C10892-1
  • dc circuit current for which designed
  • not established reliability indicator
  • 4.980 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
153-0058 NSN 6625-01-128-9279 Cross Reference: 153-58
  • ac circuit current for which designed
  • 1.812 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 3.000 inches overall height