5087 part numbers
3107450ITEM18 NSN 6625-00-382-7753 Cross Reference: 1JC86SUB3ITEM18, 1JC86SUB3ITEM2, 1JC86SUB3ITEM3, 1JC86SUB3ITEM6, 1JC86SUB3PC2, 313-6201-231511ALT1PC3, 337-6201-231851ALT3PC3, 341-6202-1183790PC3, 344-6201-839915ALT1M1PC3, 381-64-5ALT8CS1PC33
  • dc circuit current for which designed
  • 2.430 inches overall length
  • 3.280 inches center to center distance between mounting facilities parallel to length
  • 3.280 inches center to center distance between mounting facilities parallel to width
  • 3.500 inches overall height
66741 NSN 6625-00-384-8509 Cross Reference: 10688, 10688A, 4011, 4015-190, 9717A, A10101, E48468M, K10688, K9717
  • dc circuit current for which designed
  • 1.479 inches overall length
  • between 0.144 inches and 0.175 inches mounting hole diameter
  • 12 single indicator single range scale division quantity
  • between 2.625 inches and 2.656 inches overall diameter
1212 NSN 6625-00-387-5322 Cross Reference: 02431, 1212-02431
  • dc circuit current for which designed
  • 1.500 inches overall length
  • 1.320 inches center to center distance between mounting facilities parallel to length
  • 1.320 inches center to center distance between mounting facilities parallel to width
  • 1.750 inches overall height
7486001451 NSN 6625-00-391-5330 Cross Reference: 337CZ-A7, 351-F3-05, 7-486-000011, 82203, 82700, 9154571, D357BL
99-5052 NSN 6625-00-396-3052 Cross Reference: 624501, 99F50528
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 1.260 inches overall length
  • 1.240 inches center to center distance between mounting facilities parallel to length
  • 1.240 inches center to center distance between mounting facilities parallel to width
621 NSN 6625-00-400-8223 Cross Reference: 621-15119, GM805GK1
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.030 inches overall length
  • 0.124 inches mounting hole diameter
  • 50 single indicator single range scale division quantity
GM805DC1 NSN 6625-00-400-8226 Cross Reference: 2511-4901001, 9322017
  • dc circuit current for which designed
  • 5000.0 dielectric withstanding voltage in volts
  • 1.219 inches overall length
  • 1.344 inches center to center distance between mounting facilities parallel to length
  • 1.344 inches center to center distance between mounting facilities parallel to width
MT109D NSN 6625-00-401-2181
MP1250878 NSN 6625-00-401-9676
  • dc circuit current for which designed
  • nut 1; washer 1; rf shield 1 furnished items and quantity
  • panel installation design
  • 2 solder lug circuit attachment method and quantity
220G0-50ADC NSN 6625-00-402-2998 Cross Reference: 2923-212
  • dc circuit current for which designed
  • 1.640 inches overall length
  • 1.800 inches center to center distance between mounting facilities parallel to length
  • 1.880 inches center to center distance between mounting facilities parallel to width
  • 2.390 inches overall height
2931-9722058 NSN 6625-00-402-6042
  • dc circuit current for which designed
  • 4.730 inches overall length
  • 4.480 inches overall height
  • 4.210 inches overall width
  • 75 single indicator single range scale division quantity
357EX NSN 6625-00-402-6045
  • dc circuit current for which designed
  • 0.844 inches overall length
  • 8 single indicator single range scale division quantity
  • 2.203 inches overall diameter
  • dial w/pointer indicator type
CG24833-3 NSN 6625-00-403-1714
CG24833-15 NSN 6625-00-403-1716
23Y2961-10 NSN 6625-00-403-1719
291B461A27-KA-241 NSN 6625-00-403-1751 Cross Reference: 1727638
  • ac circuit current for which designed
  • 2.656 inches overall length
  • 2.376 inches center to center distance between mounting facilities parallel to length
  • 2.376 inches center to center distance between mounting facilities parallel to width
  • 4.500 inches overall height
291B461A24-KA-241 NSN 6625-00-403-1753 Cross Reference: 1727635
  • ac circuit current for which designed
  • 2.750 inches overall length
  • 2.376 inches center to center distance between mounting facilities parallel to length
  • 2.376 inches center to center distance between mounting facilities parallel to width
  • 4.500 inches overall height
750A508 NSN 6625-00-403-6581
754497 NSN 6625-00-403-8014
  • dc circuit current for which designed
  • 1.953 inches overall length
  • 50 single indicator single range scale division quantity
  • 3.590 inches overall diameter
  • 1.580 inches mounting bolt circle diameter
EM6459-1 NSN 6625-00-404-3277 Cross Reference: 731D3, 73-DMV-50U50 SCALE 200-0-200
  • dc circuit current for which designed
  • 1.172 inches overall length
  • 0.250 inches mounting stud length
  • 2.250 inches overall diameter
  • shock resistant and vibration resistant environmental protection
MS1T0-150VDC NSN 6625-00-404-6913
  • dc circuit current for which designed
  • 1.750 inches overall height
  • 1.750 inches overall width
  • panel installation design
  • black single indicator single range dial scale marking color
MS1T0-25VDC NSN 6625-00-404-6914
  • dc circuit current for which designed
  • 1.750 inches overall height
  • 1.750 inches overall width
  • panel installation design
  • black single indicator single range dial scale marking color
60902 NSN 6625-00-405-4086
1537896 NSN 6625-00-405-5787 Cross Reference: 908-Z02
  • ac and dc circuit current for which designed
  • 2.500 inches overall length
  • 3.312 inches overall height
  • 3.688 inches overall width
  • 75 single indicator all ranges scale division quantity
631 NSN 6625-00-407-0757 Cross Reference: 365-650, 631-18405, MMI-8863, SM-C-667920
  • dc circuit current for which designed
  • 2.700 inches overall length
  • between 0.143 inches and 0.157 inches mounting hole diameter
  • 10 single indicator single range scale division quantity
  • 3.510 inches overall diameter