Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches
Overall Height
1.750 inches
Overall Width
1.750 inches
Mounting Hole Diameter
0.125 inches
Environmental Protection
Hermetic and shock proof and vibration resistant
End Application
Interference generator sg-886a-t/ur
Furnished Items And Quantity
Nut 4; washer 2; gasket 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
Black single indicator single range and white single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
0.830 inches
Meter Body Diameter Behind Mounting Flange
1.500 inches
Movement Type
Moving iron vane
Background Color
Green single indicator single range and red single indicator single range and white single indicator single range
Pointer Color
Black single indicator single range
Scale Marking
Replace battery; a line at 35ua ref; operational
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Nonlinear single indicator single range
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 solder lug
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Rectangular flush mtg
Fsc Application Data
Electrical, electronic properties measuring and test instruments
Description
Meter,arbitrary Scale