Circuit Current For Which Designed
Dc
Center To Center Distance Between Mounting Facilities Parallel To Length
Between 1.306 inches and 1.318 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
Between 1.306 inches and 1.318 inches
Overall Height
1.625 inches
Overall Width
1.625 inches
Mounting Hole Diameter
Between 0.147 inches and 0.153 inches
Scale Division Quantity
20 single indicator single range
Furnished Items And Quantity
Nut 6; washer 6
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
1000.0 microamperes
Dial Scale Marking Color
Black single indicator single range and green single indicator single range
Dial Scale Marking Color
Black and green single indicator single range
Accuracy In Percent
-3.0/+3.0 at full scale single indicator single range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.000 inches
Meter Body Diameter Behind Mounting Flange
1.516 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Scale Marking
0; .4; .8; 1.2; 1.6; 2.0; green zone .5 to 1.5
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Special Markings
Green zone to left and right of centerline from .5 to 1.5 covering 45 degrees
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Radiated and conducted interference limits iaw mil-i-16910
Style Designator
Rectangular flush mtg
Supplementary Features
Internal resistance 1000.0 ohms plus or minus 1 percent over temp. Range 13 to 29 deg. Centigrade
Fsc Application Data
Test set, elect. Equip.
Description
Meter,arbitrary Scale