Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
Between 0.120 inches and 0.130 inches
Scale Division Quantity
20 single indicator 2nd range
Scale Division Quantity
20 single indicator 3rd range
Overall Diameter
2.695 inches
Environmental Protection
Shock resistant and vibration resistant
Mounting Bolt Circle Diameter
2.440 inches
Furnished Items And Quantity
Nut 5; washer 5
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
1.600 inches
Meter Body Diameter Behind Mounting Flange
2.210 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Scale Marking
Top scale: 3, 2, cal; middle scale: 0, 1, 2, 3, 4; bot scale: 0, 25, 50, 75, 100
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator 2nd range
Scale Graduation Type
Linear single indicator 3rd range
Scale Graduation Type
Nonlinear single indicator 1st range
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
Top scale: black band fm edge to 2.5 mk, black band fm 7 to 13 mk and above black band fm 8 to 12 mk
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-10304/5
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.
Description
Meter,arbitrary Scale