Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
2600.0
Mounting Hole Diameter
0.150 inches
Scale Division Quantity
40 single indicator single range
Overall Diameter
3.510 inches
Environmental Protection
Cold resistant and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Mounting Bolt Circle Diameter
3.220 inches
Furnished Items And Quantity
Nut 7; lockwasher 3; flat washer 4
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Frequency Response Range
+380.000/+420.000 hertz
Sensitivity Rating
120.0 volts
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-0.2/+0.2 at full scale single indicator single range
Meter Depth Behind Mounting Flange
4.380 inches
Meter Body Diameter Behind Mounting Flange
2.860 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+380.0/+420.0 hertz single indicator single range
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Operating Voltage Rating In Volts
Between 105.0 ac and 135.0 ac
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Complies with mil-m-10304
Style Designator
Round flush mtg
Unit Of Issue Weight
2.00 pounds
Fsc Application Data
Test set, elect. Equip.
Description
Meter,electrical Frequency