Circuit Current For Which Designed
Ac
Mounting Hole Diameter
0.151 inches
Scale Division Quantity
48 single indicator single range
Overall Diameter
3.510 inches
Mounting Bolt Circle Diameter
3.160 inches
Furnished Items And Quantity
Nut 5; washer 5
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Frequency Response Range
+388.000/+412.000 hertz
Frequency Response Range
+388.000 to 412.000 hertz
Sensitivity Rating
200.0 microamperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.660 inches
Meter Body Diameter Behind Mounting Flange
2.800 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+388.0/+412.0 hertz single indicator single range
Measurement Range
+388.0 to 412.0 hertz single indicator single range
Features Provided
Zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
Plus sign above positive terminal; sealed do not open on back of meter
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.
Description
Meter,electrical Frequency