Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
800.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.375 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.375 inches
Overall Height
4.422 inches
Overall Width
4.422 inches
Mounting Hole Diameter
0.313 inches
Scale Division Quantity
100 single indicator single range
Frequency Rating
60.0 hertz
Environmental Protection
Corrosion resistant and dust resistant and humidity resistant and shock resistant and vibration resistant
Furnished Items And Quantity
Nut 6; washer 12
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Frequency Response Range
+58.000/+62.000 hertz
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.5/+1.5 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
2.813 inches
Meter Body Diameter Behind Mounting Flange
3.960 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+58.0/+62.0 hertz single indicator single range
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Operating Voltage Rating In Volts
120.0 ac
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-16034
Style Designator
Rectangular flush mtg
Supplementary Features
Requires external transducer
Fsc Application Data
Test set, elect. Equip.
Description
Meter,electrical Frequency