Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
Between 0.120 inches and 0.130 inches
Scale Division Quantity
50 single indicator single range
Overall Diameter
2.695 inches
Environmental Protection
Shock resistant and vibration resistant
Mounting Bolt Circle Diameter
2.440 inches
End Application
Meter, modulation me-57/u
Furnished Items And Quantity
Nut 7; washer 7
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
25.0 microamperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.600 inches
Meter Body Diameter Behind Mounting Flange
2.210 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
-250.0/+250.0 kilohertz single indicator single range
Measurement Range
-250.0 to 250.0 kilohertz single indicator single range
Features Provided
Knife edge pointer and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-103o4/5
Style Designator
Round flush mtg
Supplementary Features
3000 ohm max meter res
Fsc Application Data
Test set, elect. Equip.
Description
Meter,electrical Frequency