Special Features
Measurement of ac-dc voltage frequency, resistive load and reactive load; indicates correct/incorrect phase sequence of generators, synchronization, on/off line, parallel; simulates under/over voltage conditions; derives operating power from aircraft electrical system
Width
12.000 inches
Length
15.000 inches
Ac Voltage Rating
115.0 volts
Dc Voltage Rating
28.0 volts
Frequency Rating
400.0 hertz
Electrical Power Source Relationship
Operating
Material And Location
Aluminum carrying case
Inclosure Feature
Single item w/carrying case
Test Type For Which Designed
Troubleshooting
Phase
Three
Functional Description
Used to check/trouble-shoot ac generating system, constant speed drive, frequency and load control box, ac power control assembly