Circuit Current For Which Designed
Ac and dc
Dielectric Withstanding Voltage In Volts
1000.0
Overall Depth
3.125 inches
Overall Width
5.500 inches
Scale Division Quantity
11 single indicator 1st range10 single indicator 2nd range20 single indicator 3rd range20 single indicator 4th range11 single indicator 5th range11 single indicator 6th range11 single indicator 7th range11 single indicator 8th range11 single indicator 9th range
End Application
RADA-RS-ET,-AN/T
Furnished Items And Quantity
Batteries 2, alligator clips 2
Indicator Type
Dial w/pointer
Installation Design
Bench
Frequency Response Range
+0.000/+100.000 kilohertz
Dial Scale Marking Color
Red single indicator 1st rangeblack single indicator 2nd rangeblack single indicator 3rd rangeblack single indicator 4th rangered single indicator 5th rangered single indicator 6th rangered single indicator 7th rangered single indicator 8th rangered single indicator 9th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 1st range-3.0/+3.0 at full scale single indicator 2nd range-2.0/+2.0 at full scale single indicator 3rd range-2.0/+2.0 at full scale single indicator 4th range-1.5/+1.5 at full scale single indicator 5th range-2.0/+2.0 at full scale single indicator 6th range-2.0/+2.0 at full scale single indicator 7th range-3.0/+3.0 at full scale single indicator 8th range-2.0/+2.0 at full scale single indicator 9th range
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Red single indicator all ranges
Scale Graduation Type
Linear single indicator 1st rangenonlinear single indicator 2nd rangenonlinear single indicator 3rd rangenonlinear single indicator 4th rangelinear single indicator 5th rangelinear single indicator 6th rangelinear single indicator 7th rangelinear single indicator 8th rangelinear single indicator 9th range
Measurement Range
+0.0/+10.0 amperes, dc single indicator 1st range-20.0/+50.0 decibels single indicator 2nd range+0.0/+200.0 kilohms single indicator 3rd range+0.0/+20.0 megohms single indicator 4th range+0.0/+50.0 microamperes, dc single indicator 5th range+0.0/+500.0 milliamperes, dc single indicator 6th range+0.0/+250.0 millivolts, dc single indicator 7th range+0.0/+1000.0 volts, ac single indicator 8th range+0.0/+1000.0 volts, dc single indicator 9th range
Scale Selection Method
Switch
Features Provided
Electrical overload protection and internal battery accommodation and knife edge pointer and mirror scale and portable and zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 test prod
Operating Voltage Rating In Volts
1.5 dc and 9.0 dc
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Portable