Circuit Current For Which Designed
Ac
Overall Height
4.000 inches
Overall Width
8.375 inches
Frequency Rating
Between 48.000 hertz and 440.000 hertz
Installation Design
Panel or rack
Accuracy In Percent
-0.01/+0.01 at full scale 2nd indicator all ranges
Accuracy In Percent
-0.02/+0.02 at full scale 1st indicator all ranges
Accuracy In Percent
-0.02/+0.02 at full scale 5th indicator all ranges
Accuracy In Percent
-0.5/+0.5 at full scale 3rd indicator all ranges
Accuracy In Percent
-0.8/+0.8 at full scale 4th indicator all ranges
Measurement Range
+0.0/+1.0 amperes, ac 4th indicator 1st range
Measurement Range
+0.0/+1.0 kilohms 5th indicator 1st range
Measurement Range
+0.0/+1.0 kilovolts, ac 3rd indicator 1st range
Measurement Range
+0.0/+1.0 milliamperes, ac 4th indicator 3rd range
Measurement Range
+0.0/+1.0 megohms 5th indicator 4th range
Measurement Range
+0.0/+1.0 volts, ac 3rd indicator 3rd range
Measurement Range
+0.0/+10.0 kilohms 5th indicator 2nd range
Measurement Range
+0.0/+10.0 milliamperes, ac 4th indicator 4th range
Measurement Range
+0.0/+10.0 megohms 5th indicator 5th range
Measurement Range
+0.0/+10.0 volts, ac 3rd indicator 4th range
Measurement Range
+0.0/+100.0 kilohms 5th indicator 3rd range
Measurement Range
+0.0/+100.0 microamperes, ac 4th indicator 2nd range
Measurement Range
+0.0/+100.0 milliamperes, ac 4th indicator 5th range
Measurement Range
+0.0/+100.0 millivolts, ac 3rd indicator 2nd range
Measurement Range
+0.0/+100.0 ohms 5th indicator 6th range
Measurement Range
+0.0/+100.0 volts, ac 3rd indicator 5th range
Measurement Range
-1.0/+1.0 kilovolts, dc 1st indicator 1st range
Measurement Range
-1.0/+1.0 milliamperes, dc 2nd indicator 3rd range
Measurement Range
-1.0/+1.0 amperes, dc 2nd indicator 1st range
Measurement Range
-1.0/+1.0 volts, dc 1st indicator 4th range
Measurement Range
-10.0/+10.0 millivolts, dc 1st indicator 2nd range
Measurement Range
-10.0/+10.0 milliamperes, dc 2nd indicator 4th range
Measurement Range
-10.0/+10.0 volts, dc 1st indicator 5th range
Measurement Range
-100.0/+100.0 milliamperes, dc 2nd indicator 5th range
Measurement Range
-100.0/+100.0 millivolts, dc 1st indicator 3rd range
Measurement Range
-100.0/+100.0 microamperes, dc 2nd indicator 2nd range
Measurement Range
-100.0/+100.0 volts, dc 1st indicator 6th range
Scale Selection Method
Switch
Features Provided
Electrical overload protection and self-illumination facility
Operating Voltage Rating In Volts
Between 86.0 ac and 254.0 ac
Style Designator
Rectangular surface mtg