Circuit Current For Which Designed
Ac and dc
Overall Depth
3.125 inches
Overall Width
5.250 inches
Furnished Items And Quantity
Leads 2
Indicator Type
Dial w/pointer
Installation Design
Bench
Sensitivity Rating
50.0 microamperes
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-1.5/+1.5 at full scale single indicator 7th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 10th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 11th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 12th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 1st range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 2nd range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 3rd range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 4th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 5th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 6th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 8th range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator 9th range
Accuracy In Percent
-2.5/+2.5 at full scale single indicator 13th range
Background Color
White single indicator all ranges
Pointer Color
Red single indicator all ranges
Scale Graduation Type
Linear single indicator 1st range
Scale Graduation Type
Linear single indicator 2nd range
Scale Graduation Type
Linear single indicator 3rd range
Scale Graduation Type
Linear single indicator 4th range
Scale Graduation Type
Linear single indicator 5th range
Scale Graduation Type
Linear single indicator 6th range
Scale Graduation Type
Linear single indicator 7th range
Scale Graduation Type
Linear single indicator 8th range
Scale Graduation Type
Nonlinear single indicator 10th range
Scale Graduation Type
Nonlinear single indicator 11th range
Scale Graduation Type
Nonlinear single indicator 12th range
Scale Graduation Type
Nonlinear single indicator 13th range
Scale Graduation Type
Nonlinear single indicator 9th range
Measurement Range
+0.0/+1.0 volts single indicator 1st range
Measurement Range
+0.0/+10.0 amperes, dc single indicator 8th range
Measurement Range
+0.0/+10.0 kilohms single indicator 13th range
Measurement Range
+0.0/+10.0 volts single indicator 3rd range
Measurement Range
+0.0/+1000.0 volts single indicator 6th range
Measurement Range
+0.0/+2.5 volts single indicator 2nd range
Measurement Range
+6.0/+36.0 decibels above or below one milliwatt single indicator 11th range
Measurement Range
-20.0/+10.0 decibels above or below one milliwatt single indicator 9th range
Measurement Range
-8.0/+22.0 decibels above or below one milliwatt single indicator 10th range
Measurement Range
+0.0/+50.0 microamperes, dc single indicator 7th range
Measurement Range
+0.0/+50.0 volts single indicator 4th range
Measurement Range
+0.0/+500.0 volts single indicator 5th range
Measurement Range
+20.0/+50.0 decibels above or below one milliwatt single indicator 12th range
Scale Selection Method
Switch and terminal
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
Probe, direct contact
Style Designator
Portable
Unit Of Issue Weight
3.50 pounds