Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
2000.0
Overall Height
1.430 inches
Overall Width
4.160 inches
Mounting Hole Diameter
0.165 inches
Scale Division Quantity
25 single indicator 2nd range
Distance Between Mounting Facility Centers
3.787 inches
Furnished Items And Quantity
Screw 6; nut 4; washer 2; bezel 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Two hole/stud
Frequency Response Range
+0.020 to 20.000 kilohertz
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
4.230 inches
Meter Body Width Behind Mounting Flange
3.430 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
2 unthreaded hole
Scale Graduation Type
Linear single indicator 2nd range
Scale Graduation Type
Nonlinear single indicator 1st range
Measurement Range
+0.0 to 50.0 percent modulation single indicator 2nd range
Measurement Range
-15.0/+2.0 decibels above or below one milliwatt single indicator 1st range
Measurement Range
-15.0 to 2.0 decibels above or below one milliwatt single indicator 1st range
Meter Body Height Behind Mounting Flange
1.390 inches
Features Provided
Electrical overload protection and knife edge pointer and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.
Description
Meter,multiple Scale