Circuit Current For Which Designed
Ac and dc
Dielectric Withstanding Voltage In Volts
1500.0
Mounting Hole Diameter
Between 0.143 inches and 0.157 inches
Overall Diameter
3.438 inches
Environmental Protection
Shock resistant and vibration resistant
Mounting Bolt Circle Diameter
3.160 inches
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Frequency Response Range
+25.000/+125.000 hertz
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
2.500 inches
Meter Body Diameter Behind Mounting Flange
2.210 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
3 unthreaded hole
Scale Graduation Type
Nonlinear single indicator all ranges
Measurement Range
+0.0/+10.0 milliamperes, dc single indicator 1st range
Measurement Range
+0.0/+10.0 volts, dc single indicator 3rd range
Measurement Range
+0.0/+10.0 volts, ac single indicator 2nd range
Measurement Range
+0.0/+30.0 volts, dc single indicator 4th range
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
9 solder lug
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Fsc Application Data
Test set, electronic equipment
Description
Meter,multiple Scale