Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
Between 0.143 inches and 0.157 inches
Scale Division Quantity
100 single indicator 2nd range
Scale Division Quantity
100 single indicator 3rd range
Overall Diameter
3.500 inches
Environmental Protection
Hermetic and shock resistant and vibration resistant
Mounting Bolt Circle Diameter
3.160 inches
Furnished Items And Quantity
Nut 3; washer 3; gasket 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
1.0 milliamperes
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.200 inches
Meter Body Diameter Behind Mounting Flange
2.670 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator 2nd range
Scale Graduation Type
Linear single indicator 3rd range
Scale Graduation Type
Nonlinear single indicator 1st range
Measurement Range
+0.0/+10.0 volts, dc single indicator 2nd range
Measurement Range
+0.0/+100.0 volts, dc single indicator 3rd range
Measurement Range
-100000.0/+0.0 ohms single indicator 1st range
Scale Selection Method
Terminal
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.
Description
Meter,multiple Scale