Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
1500.0
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches
Overall Height
1.750 inches
Overall Width
1.750 inches
Mounting Hole Diameter
0.125 inches
Scale Division Quantity
10 single indicator single range
Environmental Protection
Shock resistant and vibration resistant
Furnished Items And Quantity
Mtg hdw 4
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
Yellow, fluorescent single indicator single range
Accuracy In Percent
-3.0/+3.0 at full scale single indicator single range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.000 inches
Meter Body Diameter Behind Mounting Flange
1.510 inches
Movement Type
Moving coil, permanent magnet
Background Color
Black single indicator single range
Pointer Color
Yellow, fluorescent single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solderless lug
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-10304/24, mr13f5t5specr
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.