Cable assembly, special purpose; cable assembly, radio frequency
Accessory Component Quantity
1 and 2
Accessory Controlling Agency
The magnovox co
Accessory Identifying Number
W-101 part no. And w-102 part no.
Internal Battery Accommodation
Not included
Material And Location
Aluminum carrying case
Inclosure Feature
Multiple item w/carrying case
Test Type For Which Designed
Indicates signal percentages of deviation from normal; measures crystal currents; measures magnetron current; measures power supply outputs; measures range rate; measures strobe rate; provides means of disabling transmitter; rests tracking and search rate of the range tracker
Operating Test Capability
Fnullmeter, range minus 5 to plus 5 pct, minus 2 to plus 2 pct, minus 1 to plus 1pct; nullmeter range o to 40000 yds, 0 to 500 knotts, 0 to 10 v, 0 to 50 deg, 19.5 to 26.5 ma; ammeter, range 0.7 ma to 1.2 ma