Radio frequency power test set (NSN 6625-01-393-7663)
Special Features
Opt 4 includes s/9 kit: 4300 mainframe, -06 internal tma; 4311 universal channel moudle; 4312 thermocouple channel module (used only w/ thermocouple sensors); 4321 programmable calibrator 30 mhz; rack mount kit, line cord, and instruction manual; opt -5 ciil firmware revisions 460dt & 461dt
Width
17.240 inches
Length
17.750 inches
Dc Voltage Rating
100.0 volts and 120.0 volts and 220.0 volts and 240.0 volts
Frequency Rating
Between 50.0 hertz and 400.0 hertz
Furnished Items
Rack mount w/ handles p/n 950043; line cord p/n 568106000; instructions manual p/n 98401400a; ciil firmware revisions 460dt and 461dt
End Application
Radats an/gsm-370
Internal Battery Accommodation
Not included
Inclosure Feature
Single item w/housing
Measurement Unit
Average power
Input Frequency Range
+0.000/+110.000 gigahertz
Radio Frequency Input Power Rating
40.0 watts
Phase
Single
Height
3.480 inches
Supplementary Features
Power range minus 75 dbm to plus 50 dbm; range to 990 db with diode sensors and 50 db with thermocouple sensors; bnc rear panel connectors; output level is front panel/ieee bus selectable for linear or logarithmeic output 0 to 10 v; free run access time 25 ms per channel or 40 readings per sec