Special Features
100 ohms sensor ro; 10 ohms load resistance; minus 100 to plus 500 degrees f range; series 78 sensor curve; output 1 mv/degf or c; 50-60 hg; ambient temp 40-140 degrees f
Overall Depth
2.000 inches
Overall Height
3.500 inches
Overall Width
2.000 inches
Ac Voltage Rating
115.0 volts
Functional Description
Converts resistance of platinum resistance temp sensor to a millivolt per degrees output signal