Gap setting will be set for a breakdown voltage of 1200 v porm 400; breakdown voltage will be checked with a dc voltmeter across the gap and measuring peak dc when a variable source in series with the gap is slowly increased; a resistor shall be included to keep current below 1 ma
Fsc Application Data
Radio and television communication equipment, airborne