Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
1500.0
Center To Center Distance Between Mounting Facilities Parallel To Length
Between 6.045 inches and 6.055 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
Between 0.720 inches and 0.730 inches
Overall Height
1.540 inches
Overall Width
6.720 inches
Scale Division Quantity
20 single indicator single range
Mounting Stud Length
1.270 inches
Environmental Protection
Dripproof and humidity resistant and shock resistant and vibration resistant
Furnished Items And Quantity
Mtg hdw 4; term. Hdw 2
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
1.0 milliamperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
5.840 inches
Meter Body Width Behind Mounting Flange
5.435 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Red single indicator single range
Scale Marking
Psig; 0; 1; 2; 3; 4; 5; 6; 7; 8; 9; 10; 11; 12; 13; 14; 15; 16; 17; 18; 19; 20
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
Linear single indicator single range
Mounting Stud Diameter
0.190 inches
Meter Body Height Behind Mounting Flange
1.225 inches
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-24359
Style Designator
Rectangular flush mtg
Supplementary Features
Vertical mount
Fsc Application Data
Test set, elect. Equip
Description
Meter,special Scale