Circuit Current For Which Designed
Ac
Center To Center Distance Between Mounting Facilities Parallel To Length
6.000 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.000 inches
Overall Height
4.156 inches
Overall Width
6.656 inches
Mounting Hole Diameter
0.138 inches
Scale Division Quantity
100 single indicator 1st range
Scale Division Quantity
100 single indicator 3rd range
Scale Division Quantity
100 single indicator 5th range
Scale Division Quantity
100 single indicator 7th range
Scale Division Quantity
60 single indicator 2nd range
Scale Division Quantity
60 single indicator 4th range
Scale Division Quantity
60 single indicator 6th range
Scale Division Quantity
60 single indicator 8th range
Frequency Rating
Between 50.000 hertz and 60.000 hertz
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
3.750 inches
Meter Body Width Behind Mounting Flange
5.700 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
4 threaded hole
Scale Graduation Type
Linear single indicator all ranges
Measurement Range
+0.0/+0.1 volts, ac single indicator 1st range
Measurement Range
+0.0/+0.3 volts, ac single indicator 2nd range
Measurement Range
+0.0/+1.0 volts, ac single indicator 3rd range
Measurement Range
+0.0/+10.0 volts, ac single indicator 5th range
Measurement Range
+0.0/+100.0 volts, ac single indicator 7th range
Measurement Range
+0.0/+3.0 volts, ac single indicator 4th range
Measurement Range
+0.0/+30.0 volts, ac single indicator 6th range
Measurement Range
+0.0/+300.0 volts, ac single indicator 8th range
Measurement Range
+0.0 to 0.1 volts, ac single indicator 1st range
Measurement Range
+0.0 to 0.3 volts, ac single indicator 2nd range
Measurement Range
+0.0 to 1.0 volts, ac single indicator 3rd range
Measurement Range
+0.0 to 10.0 volts, ac single indicator 5th range
Measurement Range
+0.0 to 100.0 volts, ac single indicator 7th range
Measurement Range
+0.0 to 3.0 volts, ac single indicator 4th range
Measurement Range
+0.0 to 30.0 volts, ac single indicator 6th range
Measurement Range
+0.0 to 300.0 volts, ac single indicator 8th range
Scale Selection Method
Switch
Meter Body Height Behind Mounting Flange
3.780 inches
Circuit Attachment Method And Quantity
2 solder lug
Operating Voltage Rating In Volts
Between 105.0 ac and 125.0 ac
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.