Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Center To Center Distance Between Mounting Facilities Parallel To Length
Between 3.734 inches and 3.766 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
Between 2.984 inches and 3.016 inches
Overall Height
4.562 inches
Overall Width
4.562 inches
Mounting Hole Diameter
0.138 inches
Scale Division Quantity
2 single indicator single range
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
4.000 inches
Meter Body Width Behind Mounting Flange
Between 4.224 inches and 4.244 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Red single indicator single range
Mounting Facility Type And Quantity
4 threaded hole
Measurement Range
-10.0/+10.0 volts, dc single indicator 1st range
Measurement Range
-3.0/+3.0 volts, dc single indicator 2nd range
Scale Selection Method
Terminal
Meter Body Height Behind Mounting Flange
Between 4.224 inches and 4.244 inches
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
4 turret
Operating Voltage Rating In Volts
115.0 ac
Style Designator
Rectangular semi-flush mtg