Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
1500.0
Mounting Hole Diameter
0.136 inches
Overall Diameter
3.450 inches
Environmental Protection
Airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Mounting Bolt Circle Diameter
2.718 inches
Furnished Items And Quantity
Nut 3; lockwasher 3; seal 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
150.0 ohms per volt
Dial Scale Marking Color
White single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.850 inches
Meter Body Diameter Behind Mounting Flange
2.750 inches
Movement Type
Moving coil, permanent magnet
Background Color
Black single indicator single range
Pointer Color
White single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
+0.0/+300.0 volts, ac single indicator single range
Measurement Range
+0.0 to 300.0 volts, ac single indicator single range
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Special Markings
On back, sealed do not open
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Complies with mil-m-10304
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.