Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
0.150 inches
Scale Division Quantity
5 single indicator 1st range
Scale Division Quantity
6 single indicator 2nd range
Overall Diameter
3.500 inches
Environmental Protection
Shock resistant and vibration resistant
Mounting Bolt Circle Diameter
3.160 inches
Furnished Items And Quantity
Term. Hdw 2
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
20000.0 ohms per volt
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.300 inches
Meter Body Diameter Behind Mounting Flange
2.750 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
3 unthreaded hole
Scale Graduation Type
Linear single indicator all ranges
Measurement Range
+0.0/+0.1 volts, dc single indicator 1st range
Measurement Range
+0.0/+3.0 volts, dc single indicator 2nd range
Measurement Range
+0.0 to 0.1 volts, dc single indicator 1st range
Measurement Range
+0.0 to 3.0 volts, dc single indicator 2nd range
Scale Selection Method
Terminal
Features Provided
Zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to jan-i-6 and mil-m-10304
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.