Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
0.150 inches
Scale Division Quantity
50 single indicator single range
Frequency Rating
Between 50.0 hertz and 400.0 hertz
Overall Diameter
3.510 inches
Environmental Protection
Cold resistant and heat resistant and shock resistant and submersible and vibration resistant and watertight
Mounting Bolt Circle Diameter
3.160 inches
Furnished Items And Quantity
Nut 7; lockwasher 5; seal 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Frequency Response Range
+60.000/+400.000 hertz
Frequency Response Range
+60.000 to 400.000 hertz
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.660 inches
Meter Body Diameter Behind Mounting Flange
2.800 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+0.0/+500.0 volts, ac single indicator single range
Measurement Range
+0.0 to 500.0 volts, ac single indicator single range
Scale Selection Method
Terminal
Features Provided
Luminous scale marking and magnetic shield and zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Special Markings
Red line at 120, 208, 240 and 416 volts
Nuclear Hardness Critical Feature
Nonhardened
Surface Treatment Specification
Mil-f-14072 military specification single treatment response
Style Designator
Round flush mtg
Test Data Document
81349-mil-m-10304 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Specification Data
81349-mil-m-10304/16 government specification
Fsc Application Data
Test set, elect. Equip.