Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
3000.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.380 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.380 inches
Overall Height
4.330 inches
Overall Width
4.330 inches
Mounting Hole Diameter
0.312 inches
Scale Division Quantity
50 single indicator single range
Frequency Rating
Between 50.0 hertz and 60.0 hertz
Environmental Protection
Airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Furnished Items And Quantity
Nut 12; lockwasher 12; seal 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Frequency Response Range
+50.000/+60.000 hertz
Sensitivity Rating
10.0 watts
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.0/+1.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
4.000 inches
Meter Body Diameter Behind Mounting Flange
3.970 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+0.0/+5000.0 kilowatts single indicator single range
Scale Selection Method
Terminal
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
8 threaded stud
Operating Voltage Rating In Volts
120.0 ac
Special Markings
On back, studs marked 1; 2; 3; 4; 5; 6; 7; 8
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Rectangular flush mtg
Supplementary Features
Transformer rated 5 amperes
Fsc Application Data
Test set, elect. Equip.