Special Features
Power 10 to 28 vdc at 300 ma ; operatering temp minus 20 degrees celcius to plus 55 degrees celcius; altitude display range -1000 to 62000 feet; barametric pressure range 28.00 inchto 30.99 inch; level off threshold 100 feet to 1000 feet in 100 foot increments; deviation envelope adjustable buffer in the range of 100-3000 feet; alert resolution 100 foot, 10 foot when connected to shadin avionics encoder; audio output sonalert control.Eight pilot-selected audio output levels for volume and tone adjustment.Output impedance 500 ohms