Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
2000.0
Mounting Hole Diameter
0.115 inches
Scale Division Quantity
30 single indicator single range
Overall Diameter
2.695 inches
Environmental Protection
Dust resistant
Mounting Bolt Circle Diameter
2.440 inches
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
150.0 ohms per volt
Dial Scale Marking Color
White single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.660 inches
Meter Body Diameter Behind Mounting Flange
2.210 inches
Movement Type
Moving coil, permanent magnet
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+0.0/+300.0 volts, ac single indicator single range
Measurement Range
+0.0 to 300.0 volts, ac single indicator single range
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Fsc Application Data
Test set, electronic equipment