Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
1500.0
Center To Center Distance Between Mounting Facilities Parallel To Length
Between 1.306 inches and 1.318 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
Between 1.306 inches and 1.318 inches
Overall Height
Between 1.734 inches and 1.766 inches
Overall Width
Between 1.734 inches and 1.766 inches
Mounting Hole Diameter
0.125 inches
Scale Division Quantity
25 single indicator single range
Environmental Protection
Shock resistant and vibration resistant
Furnished Items And Quantity
Mtg hardware
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-3.0/+3.0 at full scale single indicator single range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.000 inches
Meter Body Diameter Behind Mounting Flange
1.500 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+0.0/+2.5 volts single indicator single range
Measurement Range
+0.0 to 2.5 volts single indicator single range
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Special Markings
Red line at mid scale; 22.5, 30 and 75 kc in blue above scale
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-10304/24, type mr13w100dcuar
Style Designator
Rectangular flush mtg
Supplementary Features
Ruggedized
Fsc Application Data
Test set, elect. Equip.